| Model | PAT 500 | PAT 1000 | PAT 2000 | PAT 3000 | |
| Rated power | 500W | 1000W | 2000W | 3000W | |
| Battery voltage | 12V DC | 12V DC | 48V DC | ||
| PV input | |||||
| Max input voltage | 60V DC | 100V DC | 150V DC | ||
| Optimum operating voltage | 16-48V DC | 33-80V DC | 65-120V DC | ||
| Max charging current | 50A | 65A | |||
| Recommended PV configuration | 700W | 1400W | 2800W | 3500W | |
| AC input | |||||
| AC input range (bypass mode) | 0-132/0-264V AC (high-end limit) | ||||
| Rated input voltage | 100/110/115/120V AC or 200/220/230/240V AC ± 25% |
||||
| Rated input frequency | 50/60± 5Hz (auto-sense) | ||||
| Max charging current | 20A | 30A | |||
| Inverter output | |||||
| Output voltage | 100/110/115/120V AC ± 2% or 200/220/230/240V AC ± 2% (settable) |
||||
| Rated output power | 500W | 1000W | 2000W | 3000W | |
| Power factor | 1 | ||||
| Rated output frequency | 50/60Hz ± 1% | ||||
| Waveform | sinusoidal | ||||
| Max efficiency (resistiveload) | ≥ 78% | ≥ 82% | ≥ 85% | ≥ 85% | |
| Sleep mode | settable (<3% load) access in ≤ 2 minutes | ||||
| Output voltage harmonic | ≤ 3% (linear load) | ||||
| Batteries | |||||
| Charging current | 5-50 A settable | 5-65 A settable | |||
| DOD | 9.6-13.0V DC/cell (settable), 10.8V DC/cell (default) | ||||
| EOD | 9.6-11.5V DC/cell (settable), 10.2V DC/cell (default) | ||||
| Equalizing charge voltage | 13.6-15.0V DC/cell (settable), 14.1V DC/cell (default) | ||||
| Floating charge voltage | 13.2-14.6V DC/cell (settable), 13.5V DC/cell (default) | ||||
| Restoration point of overvoltage | 15.5V DC | 31.0V DC | 62.0V DC | ||
| Others | |||||
| Transfer time | 3-6 minutes (typical) ≤ 10 minutes (max) |
||||
| Overload (linear load) | 105% for 5 minutes, 110% for 2 minutes, 125% for 1 minute, 150% for 10 seconds ,180% for 1 second |
||||
| ECO-friendly mode (optional) | load < 3% (settable) yes/no settable |
||||
| No-load shutdown (optional) | load < 3- 50% yes/no settable |
||||
| Load adaptation | inductive load: ≤ 30% capacitive load: ≤ 50% resistive load: ≤ 100% |
||||
| Protections | output overload-short-circuit-over-discharge –overcharge-battery reverse polarity-PV reverse polarity | ||||
| Lightning protection | Class Ⅲ | ||||
| Communications | RS232/USB/RS485/SNMP/Wi-Fi/Bluetooth (optional) | ||||
| Standards | IEC62040, IEC/EN 61000 | ||||
| IP rating | IP21 | ||||
| Display | LCD and LED | ||||